Server Upgrade
Enable Application Initialization in Internet Information Services (IIS) first before upgrading the CLIMS Server.
#
Without Ingress Setup (Standalone CLIMS)
Use this guide if the CLIMS Server will be standalone and no connection to Ingress will be made. Choose among the upgrade methods:
Double-click the new installer file.
In the setup wizard, click Next.
Welcome Screen
Read and accept the License Agreement, then click Next.
End-User License Agreement
The installer automatically detects the previous installation directories.
Click Change to specify new directories; otherwise, click Next.
Destination Folder
Changing the Installation Directories
Specify a valid Open iT license file, then click Next.
Open iT License File
You may skip this step and upload a valid license file through the CLIMS Server web interface afterward.
Click Next to skip the prompt for specifying the Open iT Ingress URI.
Ingress URI Details
Click Yes to proceed with the installation.
Warning for Inaccessible Ingress URI
Click Install to start the upgrade process.
Alternatively, click Back to review any installation setting.
Ready to Install
The installer will set up all necessary files on the computer. Click Finish.
Complete Installation
Open a command prompt with Administrator level privileges.
Run the following command:
Command Syntaxmsiexec /i <path_to_installer> /l*v <path_to_logfile> [/quiet] [/passive] <LICENSEFILE> <INSTALLDIR> <DATADIR> <SERVERPORT>
Command Parameters
The installation will use the default directories and port number if these properties are unspecified.
Also, the installer will use the Windows Installer Interface if the process mode (
/quiet
or/passive
) is unspecified.Examples
To install
openit_10_2_0_clims_server_x64.msi
, fromC:\Installers
, in unattended mode with all logging information stored in an output log file atC:\install.log
and using the license file,C:\Users\OpeniT\Documents\openit_license
, and the default directories and port number:Example 1msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive LICENSEFILE="C:\Users\OpeniT\Documents\openit_license"
To install
openit_10_2_0_clims_server_x64.msi
fromC:\Installers
in silent mode with all logging information stored in an output log file atC:\install.log
, and using a preferred installation and data directories and default port number:Example 2msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /quiet INSTALLDIR="C:\CLIMSServer" DATADIR="C:\CLIMSData"
To install
openit_10_2_0_clims_server_x64.msi
fromC:\Installers
in unattended mode with all logging information stored in an output log file atC:\install.log
, and using the default directories and 8889 as the port number:Example 3msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive SERVERPORT="8889"
When using the passive mode, wait until the process bar dialog disappears.
When using the quiet mode, verify that the installation is complete by opening the Task Manager and checking in the Details tab if the msiexec process is still running.
#
With Ingress Setup
Use this guide if the CLIMS Server will connect to Ingress (local or remote).
#
Local Ingress Setup
Install Open iT Ingress first before upgrading to CLIMS Server version 10.
Use this guide if Ingress is installed locally or on the same machine as the CLIMS Server. This assumes that Ingress is properly installed and accessible. Choose among the upgrade methods:
Double-click the new installer file.
In the setup wizard, click Next.
Welcome Screen
Read and accept the License Agreement, then click Next.
End-User License Agreement
The installer automatically detects the previous installation directories.
Click Change to specify new directories; otherwise, click Next.
Destination Folder
Changing the Installation Directories
Specify a valid Open iT license file, then click Next.
Open iT License File
You may skip this step and upload a valid license file through the CLIMS Server web interface afterward.
Click Install to start the upgrade process.
Alternatively, click Back to review any installation setting.
Ready to Install
The installer will set up all necessary files on the computer. Click Finish.
Complete Installation
Open a command prompt with Administrator level privileges.
Run the following command:
Command Syntaxmsiexec /i <path_to_installer> /l*v <path_to_logfile> [/quiet] [/passive] <INGRESSURI> <LICENSEFILE> <INSTALLDIR> <DATADIR> <SERVERPORT>
Command Parameters
The installation will use the default directories and port number if these properties are unspecified.
Also, the installer will use the Windows Installer Interface if the process mode (
/quiet
or/passive
) is unspecified.
Examples
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in unattended mode with all logging information stored in an output log file at C:\install.log
and using the license file, C:\Users\OpeniT\Documents\openit_license
, default directories and port number, and https://customer.openit.com
as the Ingress URI:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive LICENSEFILE="C:\Users\OpeniT\Documents\openit_license" INGRESSURI=https://customer.openit.com
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in silent mode with all logging information stored in an output log file at C:\install.log
, and using a preferred installation and data directories and default port number:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /quiet INSTALLDIR="C:\CLIMSServer" DATADIR="C:\CLIMSData"
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in unattended mode with all logging information stored in an output log file at C:\install.log
, and using the default directories and 8889 as the port number:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive SERVERPORT="8889"
When using the passive mode, wait until the process bar dialog disappears.
When using the quiet mode, verify that the installation is complete by opening the Task Manager and checking in the Details tab if the msiexec process is still running.
#
Remote Ingress Setup
Install Open iT Ingress first before upgrading to CLIMS Server version 10.
Use this guide if Ingress is installed remotely or on a separate machine than the CLIMS Server. This assumes that Ingress is properly installed, accessible, and the URI is ready. Choose among the upgrade methods:
Double-click the new installer file.
In the setup wizard, click Next.
Welcome Screen
Read and accept the License Agreement, then click Next.
End-User License Agreement
The installer automatically detects the previous installation directories.
Click Change to specify new directories; otherwise, click Next.
Destination Folder
Changing the Installation Directories
Specify a valid Open iT license file, then click Next.
Open iT License File
You may skip this step and upload a valid license file through the CLIMS Server web interface afterward.
Specify the Open iT Ingress URI where the CLIMS Server will connect to, then click Next.
Ingress URI Details
A warning prompt will appear if the Open iT Ingress is inaccessible. This may also occur if Open iT Ingress is not yet installed.
Click Yes to proceed with the installation.
Warning for Inaccessible Ingress URI
Click Install to start the upgrade process.
Alternatively, click Back to review any installation setting.
Ready to Install
The installer will set up all necessary files on the computer. Click Finish.
Complete Installation
Open a command prompt with Administrator level privileges.
Run the following command:
Command Syntaxmsiexec /i <path_to_installer> /l*v <path_to_logfile> [/quiet] [/passive] <INGRESSURI> <LICENSEFILE> <INSTALLDIR> <DATADIR> <SERVERPORT>
Command Parameters
The installation will use the default directories and port number if these properties are unspecified.
Also, the installer will use the Windows Installer Interface if the process mode (
/quiet
or/passive
) is unspecified.
Examples
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in unattended mode with all logging information stored in an output log file at C:\install.log
and using the license file, C:\Users\OpeniT\Documents\openit_license
, default directories and port number, and https://customer.openit.com
as the Ingress URI:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive LICENSEFILE="C:\Users\OpeniT\Documents\openit_license" INGRESSURI=https://customer.openit.com
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in silent mode with all logging information stored in an output log file at C:\install.log
, and using a preferred installation and data directories and default port number:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /quiet INSTALLDIR="C:\CLIMSServer" DATADIR="C:\CLIMSData"
To install openit_10_2_0_clims_server_x64.msi
from C:\Installers
in unattended mode with all logging information stored in an output log file at C:\install.log
, and using the default directories and 8889 as the port number:
msiexec /i "C:\Installers\openit_10_2_0_clims_server_x64.msi" /l*v "C:\install.log" /passive SERVERPORT="8889"
When using the passive mode, wait until the process bar dialog disappears.
When using the quiet mode, verify that the installation is complete by opening the Task Manager and checking in the Details tab if the msiexec process is still running.
#
Next Steps?
After upgrading, proceed with verifying the upgrade.
Verifying CLIMS Server Installation
If you upgraded to CLIMS Server version 10 first and then installed Ingress later, proceed with manually configuring the CLIMS Server connection to Ingress.