EasyCopy License Manager
#
Introduction
Open iT supports EasyCopy usage reporting by polling the license servers at regular intervals to get the current status of its license use and availability. This will produce the following aggregated data types used for historical reporting:
- (49) Host User License Use
- (93) OLAP Raw Hourly
- (94) OLAP User Concurrency
- (95) Usergroup License Use v3.0
- (102) OLAP Total Use
The following sections will guide you in setting up the necessary configuration to collect and send the required data to the server.
Apply the configurations shown in the Open iT client.
#
Requirements
- An Open iT Client connected to an Open iT Server or a coexistent Open iT setup
- Activated LicenseAnalyzer collection and license poller
- License server administrative rights
- Running license manager utility binary and its
location
#
Getting the License Status Utility Binary Location
This configuration requires the path to the license status utility binary, eclic
, to obtain the license status information. Get this by following these steps:
Through the Interface
- Open the Task Manager.
- Go to the Details tab.
- Locate
eclic
. - Right-click and choose Open file location.
The path of the binary will be displayed.
Through the Command Line
Open a command prompt with Administrator level privileges.
Run the following command to locate the binary:
Command Syntaxwhere /r <installation_drive> eclic
where <installation_drive> is the drive where the license manager is installed.
Examplewhere /r C:\ eclic
The path of the binary will be displayed.
After verifying the path of the polling program, make sure that it is running.
Open a command prompt in the directory of the license server executable or the polling program and run the following command:
eclic
Make sure that there are no errors encountered.
Run the following command to locate the binary:
find . | grep eclic
The path of the binary will be displayed.
#
Configuring Data Collection
These are the required steps to activate and configure collection of EasyCopy usage data.
Go to the Components directory, which is by default in
C:\Program Files\OpeniT\Core\Configuration\Components
, and back up thelicpoll.xml
configuration file.Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Once in the directory, activate the collection of EasyCopy data, run the command:
Command Syntaxopenit_confinit -c "licpoll.license-types.easycopy-sample.active=true"
Set the path to the binary used by the EasyCopy License Server, run the command:
Command Syntaxopenit_confinit -c "licpoll.license-types.easycopy-sample.status-command=<binary_path>"
where binary_path is the obtained path in
Getting the License Status Utility Binary Path .Exampleopenit_confinit -c "licpoll.license-types.easycopy-sample.status-command=C:\EasyCopy\eclic"
Set the arguments to the status command to
XMLINFO
, run the command:Command Syntaxopenit_confinit -c "licpoll.license-types.easycopy-sample.status-command.arguments=XMLINFO"
Update the configuration file, run the command:
Command Syntaxopenit_confbuilder --client
Make sure that there are no errors encountered.
These instructions assume that your etc directory is in /var/opt/openit
.
Go to the Components directory, which is by default in
/var/opt/openit/etc/Components
, and back up thelicpoll.xml
configuration file.Go to the bin directory, which is by default in
/opt/openit/bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd /opt/openit/bin
Once in the directory, activate the collection of EasyCopy data, run the command:
Command Syntax./openit_confinit -r /var/opt/openit/ -d /var/opt/openit/etc/ -c "licpoll.license-types.easycopy-sample.active=true"
Set the path to the binary used by the EasyCopy License Server, run the command:
Command Syntax./openit_confinit -r /var/opt/openit/ -d /var/opt/openit/etc/ -c "licpoll.license-types.easycopy-sample.status-command=<binary_path>"
where <binary_path> is the obtained path in
Getting the License Status Utility Binary Path .Example./openit_confinit -r /var/opt/openit/ -d /var/opt/openit/etc/ -c "licpoll.license-types.easycopy-sample.status-command=/var/opt/easycopy/clearlicense"
Set the arguments to the status command to
XMLINFO
, run the command:Command Syntax./openit_confinit -r /var/opt/openit/ -d /var/opt/openit/etc/ -c "licpoll.license-types.easycopy-sample.status-command.arguments=XMLINFO"
Update the configuration file, run the command:
Command Syntax./openit_confbuilder --client
Make sure that there are no errors encountered.
Refer to the EasyCopy Data Collection Configuration table to learn more about EasyCopy configuration in licpoll.xml
.
#
Verifying Data Collection
After configuration, you can verify that the data is collected by following these steps:
Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Run the command:
Command Syntaxopenit_licpoll -# 1
Verify that the temp directory, which is by default in
C:\ProgramData\OpeniT\Data\temp
, contains aLicPoll
directory containing.data
andstatus-*.log
files.
Go to the bin directory, which is by default in
/opt/openit/bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd /opt/openit/bin
Run the command:
Command Syntax./openit_licpoll -# 1
Verify that the temp directory, which is by default in
/var/opt/openit/temp
, contains aLicPoll
directory containing.data
andstatus-*.log
files.
#
Next Steps?