Altium Concord Pro
#
Introduction
Open iT supports Altium Concord Pro usage reporting through the generic license type format. This will produce the following aggregated data types used for historical reporting:
- (49) Host User License Use
- (93) OLAP Raw Hourly
- (94) OLAP User Concurrency
- (95) Usergroup License Use v3.0
- (102) OLAP Total Use
The following sections will guide you in setting up the necessary configuration to collect and send the required data to the server.
Apply the configurations shown in the Open iT client.
#
Requirements
- An Open iT Client connected to an Open iT Server or a coexistent Open iT setup
- Activated LicenseAnalyzer collection and license poller
- Configured Altium Concord License Server
- Valid URL with the port number of the Altium Concord API
#
Configuring Data Collection
These are the required steps to activate and configure collection of Altium Concord usage data.
Go to the Components directory, which is by default in
C:\Program Files\OpeniT\Core\Configuration\Components
, and back up thelicpoll.xml
configuration file.Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Once in the directory, copy the object node
genericlicense-sample
, and rename it to your desired name. In this example, we will usealtiumconcordpro
. Run the command:Command Syntaxopenit_confinit -c "licpoll.license-types.genericlicense-sample=>licpoll.license-types.altiumconcordpro"
Element names cannot contain parentheses ( or ) because they are not valid for XML element names.
Activate the collection of Altium Concord Pro data, run the command:
Command Syntaxopenit_confinit -c "licpoll.license-types.altiumconcordpro.active=true"
Set the arguments to the status command, run the command:
Command Syntaxopenit_confinit -c "licpoll.license-types.altiumconcordpro.status-command.arguments=AltiumConcord <api_url>"
where
<api_url>
is the corresponding valid URL with the port number of the AltiumConcord API.Exampleopenit_confinit -c "licpoll.license-types.altiumconcordpro.status-command.arguments=AltiumConcord http://localhost:1804"
Update the configuration file, run the command:
Command Syntaxopenit_confbuilder --client
Make sure that there are no errors encountered.
Refer to the Altium Concord Data Collection Configuration table to learn more about Altium Concord configuration in licpoll.xml
.
#
Verifying Data Collection
After configuration, you can verify that the data is collected by following these steps:
Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Run the command:
Command Syntaxopenit_licpoll -# 1
Verify that the temp directory, which is by default in
C:\ProgramData\OpeniT\Data\temp
, contains aLicPoll
directory containing.data
andstatus-*.log
files.
#
Next Steps?