Altium License Manager
#
Introduction
Open iT supports Altium usage reporting by collecting log files and converting them to Open iT format. This will produce the following aggregated data types used for historical reporting:
- (89) Total License Use Licenseevents
- (90) Individual License Use Licenseevents
- (91) Usergroup License Use Licenseevents
- (108) Host License Use Licenseevents
- (109) Hostgroup License Use Licenseevents
- (104) License Logfile Events v2.0
- (107) Denied License Use Licenseevents
The following sections will guide you in setting up the necessary configuration to collect and send the required data to the server.
Apply the configurations shown in the Open iT client.
#
Requirements
- An Open iT Client connected to an Open iT Server or a coexistent Open iT setup
- License server administrative rights
- Full path to the debug log file
#
Configuring Log File Collection
These are the required steps to configure collection of Altium log files.
Go to the Components directory, which is by default in
C:\Program Files\OpeniT\Core\Configuration\Components
, and openlogfilecollector-altium.xml
.Locate object node
dir
and set its value to the location of the Altium log files.logfilecollector-altium.xml14| <Object> 15| <Name>dir</Name> 16| <Description>Directory containing the log files</Description> 17| <Value type="DirName">%ALTIUM%</Value> 18| </Object>
Example: logfilecollector-altium.xml14| <Object> 15| <Name>dir</Name> 16| <Description>Directory containing the log files</Description> 17| <Value type="DirName">C:\Users\Administrator\Desktop\altium</Value> 18| </Object>
Save the changes.
Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Update the configuration file, run the command:
Command Syntaxopenit_confbuilder --client
Make sure that there are no errors encountered.
Refer to the Altium Log File Collection Configuration table to learn more about Altium configuration in logfilecollector-altium.xml
.
#
Activating Log Data Collection
These are the required steps to activate collection of Altium log data.
Go to the scheduler directory, which is by default in
C:\Program Files\OpeniT\Core\Configuration\scheduler
, and opencollect_license_altium-logs.oconf
.Locate and set
root.scheduler.jobs.collect_altium_licenselogs.general.active
to true to activate the collection of Altium log data.collect_license_altium-logs.oconf13| } 14| general 15| { 16| active 17| { 18| type=bool 19| value=true
Save the changes.
The collection runs hourly using a 5-minute sample interval by default. The primary data is then transferred to the server every night according to the client timezone for processing. To configure the intervals, locate the instances
attribute under collect_altium_licenselogs
, preprocess_altium_licenselogs-events
, preprocess_altium_licenselogs-records
, or transfer_altium_licenselogs
in the same file and configure the attributes.
Refer to the Altium Log Job Scheduler Instances Configuration table to learn the attributes used to configure Altium data collection and transfer.
#
Verifying Log Data Collection
After configuration, you can verify that the data is collected and sent to the server by following these steps:
Open a command prompt with Administrator level privileges.
Go to the bin directory, which is by default in
C:\Program Files\OpeniT\Core\bin
, run the command:Command Syntaxcd $BIN_DIR
Examplecd C:\Program Files\OpeniT\Core\bin
Run the command:
Command Syntaxopenit_executor -r collect_license_altium-logs
Verify that there are
archiver*.in
files created in the server in the archiver directory, which is by default inC:\ProgramData\OpeniT\Data\incoming\archiver
.
Next Steps? Renaming Vendor License Renaming Features Create and Add Report License Monitor